2009
A prospective follow-up study of 44 mandibular immediately loaded implants using resonance frequency analysis: preliminary 1-year results.
Authors: Melo Ana Cláudia Moreira (AC) ; de Freitas Maurício Correia (MC) ; Bernardes Sergio Rocha (SR) ; de Mattias Sartori Ivete Aparecida (IA) ; Bassi Ana Paula Farnezi (AP) ; Thomé Geninho (G) ;
Published in: Implant Dent, 2009 Dec
Read more
Pubmed link
Potential damage to bone-implant interface when measuring initial implant stability.
Authors: Seong Wook-Jin (WJ) ; Conrad Heather J (HJ) ; Hinrichs James E (JE) ;
Published in: J. Periodontol., 2009 Nov
Read more
Pubmed link
Is the osseointegration of immediately and delayed loaded implants the same?--comparison of the implant stability during a 3-month healing period in a prospective study.
Authors: Zhou Wei (W) ; Han Chun (C) ; Yunming Li (L) ; Li Dehua (D) ; Song Yingliang (Y) ; Zhao Yimin (Y) ;
Published in: Clin Oral Implants Res, 2009 Dec
Read more
Pubmed link
Implant placement for periosteal expansion osteogenesis using beta-tricalcium phosphate block: an experimental study in dogs.
Authors: Yamauchi Kensuke (K) ; Takahashi Tetsu (T) ; Funaki Katsuyuki (K) ; Miyamoto Ikuya (I) ; Yamashita Yoshihiro (Y) ;
Published in: Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 2009 Dec
Read more
Pubmed link
Clinical study on the insertion torque and wireless resonance frequency analysis in the assessment of torque capacity and stability of self-tapping dental implants.
Authors: Kahraman S (S) ; Bal B T (BT) ; Asar N V (NV) ; Turkyilmaz I (I) ; Tözüm T F (TF) ;
Published in: J Oral Rehabil, 2009 Oct
Read more
Pubmed link
Resonance frequency measurements in vivo and related surface properties of magnesium-incorporated, micropatterned and magnesium-incorporated TiUnite, Osseotite, SLA and TiOblast implants.
Authors: Sul Young-Taeg (YT) ; Jönsson Jörgen (J) ; Yoon Goui-Seong (GS) ; Johansson Carina (C) ;
Published in: Clin Oral Implants Res, 2009 Oct
Read more
Pubmed link
In vitro evaluation of the type of implant bed preparation with osteotomes in bone type IV and its influence on the stability of two implant systems.
Authors: García-Vives Nuria (N) ; Andrés-García Rodrigo (R) ; Rios-Santos Vicente (V) ; Fernández-Palacín Ana (A) ; Bullón-Fernández Pedro (P) ; Herrero-Climent Mariano (M) ; Herrero-Climent Federico (F) ;
Published in: Med Oral Patol Oral Cir Bucal, 2009 Sep
Read more
Pubmed link
Endodontic treatment of teeth induces retrograde peri-implantitis.
Authors: Zhou Wei (W) ; Han Chun (C) ; Li Dehua (D) ; Li Yunming (Y) ; Song Yingliang (Y) ; Zhao Yimin (Y) ;
Published in: Clin Oral Implants Res, 2009 Dec
Read more
Pubmed link
Comparison of two bone substitute biomaterials consisting of a mixture of fibrin sealant (Tisseel) and MBCP (TricOs) with an autograft in sinus lift surgery in sheep.
Authors: Saffarzadeh Afchine (A) ; Gauthier Olivier (O) ; Bilban Melitta (M) ; Bagot D'Arc Maurice (M) ; Daculsi Guy (G) ;
Published in: Clin Oral Implants Res, 2009 Oct
Read more
Pubmed link
Implant stability and bone density: assessment of correlation in fresh cadavers using conventional and osteotome implant sockets.
Authors: Cehreli Murat Cavit (MC) ; Kökat Ali Murat (AM) ; Comert Ayhan (A) ; Akkocaoğlu Murat (M) ; Tekdemir Ibrahim (I) ; Akça Kivanç (K) ;
Published in: Clin Oral Implants Res, 2009 Oct
Read more
Pubmed link
Measurement of dental implant stability by resonance frequency analysis: a review of the literature.
Authors: Quesada-García Maria-Pilar (MP) ; Prados-Sánchez Estrella (E) ; Olmedo-Gaya Maria-Victoria (MV) ; Muñoz-Soto Esther (E) ; González-Rodríguez Maria-Paloma (MP) ; Valllecillo-Capilla Manuel (M) ;
Published in: Med Oral Patol Oral Cir Bucal, 2009 Oct
Read more
Pubmed link
The possible association among bone density values, resonance frequency measurements, tactile sense, and histomorphometric evaluations of dental implant osteotomy sites: a preliminary study.
Authors: Aksoy Utku (U) ; Eratalay Kenan (K) ; Tözüm Tolga F (TF) ;
Published in: Implant Dent, 2009 Aug
Read more
Pubmed link
Increased bone formation around coated implants.
Authors: Stadlinger Bernd (B) ; Bierbaum Susanne (S) ; Grimmer Silke (S) ; Schulz Matthias C (MC) ; Kuhlisch Eberhard (E) ; Scharnweber Dieter (D) ; Eckelt Uwe (U) ; Mai Ronald (R) ;
Published in: J. Clin. Periodontol., 2009 Aug
Read more
Pubmed link
Fresh-frozen vs. embalmed bone: is it possible to use formalin-fixed human bone for biomechanical experiments on implants?
Authors: Cömert Ayhan (A) ; Kökat Ali Murat (AM) ; Akkocaoğlu Murat (M) ; Tekdemir Ibrahim (I) ; Akça Kivanç (K) ; Cehreli Murat Cavit (MC) ;
Published in: Clin Oral Implants Res, 2009 May
Read more
Pubmed link
Correlating implant stability to bone structure.
Authors: Rozé Julie (J) ; Babu Stéphanie (S) ; Saffarzadeh Afchine (A) ; Gayet-Delacroix Marie (M) ; Hoornaert Alain (A) ; Layrolle Pierre (P) ;
Published in: Clin Oral Implants Res, 2009 Oct
Read more
Pubmed link
[Immediate loading of implants in fully edentulous jaws: two cases report].
Authors: Huang Jian-Sheng (JS) ; Zhu Xiao-Bin (XB) ;
Published in: Hua Xi Kou Qiang Yi Xue Za Zhi, 2009 Apr
Read more
Pubmed link
Influence of residual alveolar bone height on implant stability in the maxilla: an experimental animal study.
Authors: Fenner Matthias (M) ; Vairaktaris Eleftherios (E) ; Stockmann Philipp (P) ; Schlegel Karl Andreas (KA) ; Neukam Friedrich Wilhelm (FW) ; Nkenke Emeka (E) ;
Published in: Clin Oral Implants Res, 2009 Aug
Read more
Pubmed link
Assessment of dental implant stability in osseodistraction-generated bone: a resonance frequency analysis.
Authors: Bilbao Arturo (A) ; Oliveira M Hernández-De (MH) ; Varela-Centelles Pablo I (PI) ; Seoane J (J) ;
Published in: Clin Oral Implants Res, 2009 Aug
Read more
Pubmed link
Immediate loading of immediate mandibular implants with a full-arch fixed prosthesis: a preliminary study.
Authors: Peñarrocha Miguel (M) ; Boronat Araceli (A) ; Garcia Berta (B) ;
Published in: J. Oral Maxillofac. Surg., 2009 Jun
Read more
Pubmed link
Early loading of nonsubmerged titanium implants with a chemically modified sand-blasted and acid-etched surface: 6-month results of a prospective case series study in the posterior mandible focusing on peri-implant crestal bone changes and implant stability quotient (ISQ) values.
Authors: Bornstein Michael M (MM) ; Hart Christopher N (CN) ; Halbritter Sandro A (SA) ; Morton Dean (D) ; Buser Daniel (D) ;
Published in: Clin Implant Dent Relat Res, 2009 Dec
Read more
Pubmed link
Sinus implants stabilization in Misch IV Class by means of S.I.S. device: A Clinical Study.
Authors: Grandi C (C) ; Pacifici L (L) ;
Published in: Oral Implantol (Rome), 2009 Oct
Read more
Pubmed link
Soft bone primary stability of 3 different miniscrews for orthodontic anchorage: a resonance frequency investigation.
Authors: Veltri Mario (M) ; Balleri Beatrice (B) ; Goracci Cecilia (C) ; Giorgetti Roberto (R) ; Balleri Piero (P) ; Ferrari Marco (M) ;
Published in: Am J Orthod Dentofacial Orthop, 2009 May
Read more
Pubmed link
Tapered implants: from indications to advantages.
Authors: Alves Célia Coutinho (CC) ; Neves Manuel (M) ;
Published in: Int J Periodontics Restorative Dent, 2009 Apr
Read more
Pubmed link
Glycemic control and implant stabilization in type 2 diabetes mellitus.
Authors: Oates T W (TW) ; Dowell S (S) ; Robinson M (M) ; McMahan C A (CA) ;
Published in: J. Dent. Res., 2009 Apr
Read more
Pubmed link
Implant stability in relation to osseointegration: an experimental study in the Labrador dog.
Authors: Abrahamsson Ingemar (I) ; Linder Elena (E) ; Lang Niklaus P (NP) ;
Published in: Clin Oral Implants Res, 2009 Mar
Read more
Pubmed link
Histological findings following the use of a space-making device for bone reformation and implant integration in the maxillary sinus of primates.
Authors: Cricchio Giovanni (G) ; Palma Vinícius Canavarros (VC) ; Faria Paulo E P (PE) ; de Oliveira José Américo (JA) ; Lundgren Stefan (S) ; Sennerby Lars (L) ; Salata Luiz A (LA) ;
Published in: Clin Implant Dent Relat Res, 2009 Oct
Read more
Pubmed link
Human ex vivo bone tissue strains around immediately-loaded implants supporting mandibular fixed prostheses.
Authors: Kökat Ali Murat (AM) ; Cömert Ayhan (A) ; Tekdemir Ibrahim (I) ; Akkocaoğlu Murat (M) ; Akça Kvanç (K) ; Cehreli Murat Cavit (MC) ;
Published in: Implant Dent, 2009 Apr
Read more
Pubmed link
Application of radiofrequency ablation of renal VX2 tumors by cooled-tip electrode in a rabbit model.
Authors: Ho Yungjen (Y) ; Huang Yongsan (Y) ; Lin Chunming (C) ; Chung Chihlin (C) ; Lin Yungchang (Y) ;
Published in: J. Endourol., 2009 Apr
Read more
Pubmed link
Stability change of chemically modified sandblasted/acid-etched titanium palatal implants. A randomized-controlled clinical trial.
Authors: Schätzle Marc (M) ; Männchen Roland (R) ; Balbach Ulrike (U) ; Hämmerle Christoph H F (CH) ; Toutenburg Helge (H) ; Jung Ronald E (RE) ;
Published in: Clin Oral Implants Res, 2009 May
Read more
Pubmed link
Influence of the orientation of the Osstell transducer during measurement of dental implant stability using resonance frequency analysis: a numerical approach.
Authors: Capek Lukas (L) ; Simunek Antonin (A) ; Slezak Radovan (R) ; Dzan Ladislav (L) ;
Published in: Med Eng Phys, 2009 Sep
Read more
Pubmed link
Immediate occlusal loading of immediately placed implants supporting fixed restorations in completely edentulous arches: a 1-year prospective pilot study.
Authors: Pieri Francesco (F) ; Aldini Nicolò Nicoli (NN) ; Fini Milena (M) ; Corinaldesi Giuseppe (G) ;
Published in: J. Periodontol., 2009 Mar
Read more
Pubmed link
Reliability and validity of the instrumental assessment of implant stability in dry human mandibles.
Authors: Brouwers J E I G (JE) ; Lobbezoo F (F) ; Visscher C M (CM) ; Wismeijer D (D) ; Naeije M (M) ;
Published in: J Oral Rehabil, 2009 Apr
Read more
Pubmed link
Application of Radiofrequency Ablation of Renal VX2Tumors by Cooled-Tip Electrode in a Rabbit Model.
Authors: Ho Y (Y) ; Huang Y (Y) ; Lin C (C) ; Chung C (C) ; Lin Y (Y) ;
Published in: IEEE Trans Nanobioscience, 2009 Feb
Read more
Pubmed link
In vitro evaluation of the influence of the cortical bone on the primary stability of two implant systems.
Authors: Andrés-García Rodrigo (R) ; Vives Nuria García (NG) ; Climent Federico Herrero (FH) ; Palacín Ana Fernández (AF) ; Santos Vicente Ríos (VR) ; Climent Mariano Herrero (MH) ; Bullón Pedro (P) ;
Published in: Med Oral Patol Oral Cir Bucal, 2009 Feb
Read more
Pubmed link
Horizontal alveolar ridge augmentation using distraction osteogenesis: comparison with a bone-splitting method in a dog model.
Authors: Funaki Katsuyuki (K) ; Takahashi Tetsu (T) ; Yamuchi Kensuke (K) ;
Published in: Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 2009 Mar
Read more
Pubmed link
2008
Influence of bone density on implant stability parameters and implant success: a retrospective clinical study.
Authors: Turkyilmaz Ilser (I) ; McGlumphy Edwin A (EA) ;
Published in: BMC Oral Health, 2008
Read more
Pubmed link
[A preliminary study on alveolar bone and teeth defect by immediate autologous bone graft and secondary dental implantation].
Authors: Tong Qing-Chun (QC) ; Li Ning-Yi (NY) ; Zhang Zhi-Yong (ZY) ; Lv Kai-Ge (KG) ;
Published in: Shanghai Kou Qiang Yi Xue, 2008 Oct
Read more
Pubmed link
Simultaneous dental implant placement and endoscope-guided internal sinus floor elevation: 2-year post-loading outcomes.
Authors: Schleier Peter (P) ; Bierfreund Gerrit (G) ; Schultze-Mosgau Stefan (S) ; Moldenhauer Franziska (F) ; Küpper Harald (H) ; Freilich Martin (M) ;
Published in: Clin Oral Implants Res, 2008 Nov
Read more
Pubmed link
Two-year prospective clinical comparison of immediate replacement vs. immediate restoration of single tooth in the esthetic zone.
Authors: Palattella Piermario (P) ; Torsello Ferruccio (F) ; Cordaro Luca (L) ;
Published in: Clin Oral Implants Res, 2008 Nov
Read more
Pubmed link
Early loading of ITI implants supporting maxillary fixed full-arch prostheses.
Authors: Lai Hong-Chang (HC) ; Zhang Zhi-Yong (ZY) ; Zhuang Long-Fei (LF) ; Wang Feng (F) ; Liu Xin (X) ; Pu Yi-Ping (YP) ;
Published in: Clin Oral Implants Res, 2008 Nov
Read more
Pubmed link
One-year outcome of narrow diameter blasted implants for rehabilitation of maxillas with knife-edge resorption.
Authors: Veltri M (M) ; Ferrari M (M) ; Balleri P (P) ;
Published in: Clin Oral Implants Res, 2008 Oct
Read more
Pubmed link
Immediate loading and immediate restoration in 105 expanded-platform implants via the Diem System after a 16-month follow-up period.
Authors: Calvo Guirado Jose Luis (JL) ; Ortiz Ruiz Antonio José (AJ) ; Gómez Moreno Gerardo (G) ; López Marí Laura (L) ; Bravo González Luis Alberto (LA) ;
Published in: Med Oral Patol Oral Cir Bucal, 2008 Sep
Read more
Pubmed link
Resonance frequency analysis of long-term implant success in the posterior partially edentulous mandible.
Authors: Yamaguchi Masahiko (M) ; Xu Hui (H) ; Shimizu Yoshinaka (Y) ; Hatano Naoki (N) ; Ooya Kiyoshi (K) ;
Published in: Quintessence Int, 2008 Mar
Read more
Pubmed link
A comparison of stability between delayed versus immediately loaded orthodontic palatal implants.
Authors: Jackson Amy (A) ; Lemke Robert (R) ; Hatch John (J) ; Salome Norman (N) ; Gakunga Peter (P) ; Cochran David (D) ;
Published in: J Esthet Restor Dent, 2008
Read more
Pubmed link
Initial stability measurement of dental implants placed in different anatomical regions of fresh human cadaver jawbone.
Authors: Seong Wook-Jin (WJ) ; Holte James E (JE) ; Holtan James R (JR) ; Olin Paul S (PS) ; Hodges James S (JS) ; Ko Ching-Chang (CC) ;
Published in: J Prosthet Dent, 2008 Jun
Read more
Pubmed link
Effect of strain at low-frequency loading on peri-implant bone (re)modelling: a guinea-pig experimental study.
Authors: De Smet Els (E) ; Jaecques Siegfried V N (SV) ; Jansen John J (JJ) ; Walboomers Frank (F) ; Vander Sloten Jos (J) ; Naert Ignace E (IE) ;
Published in: Clin Oral Implants Res, 2008 Aug
Read more
Pubmed link
Is there a lower threshold value of bone density for early loading protocols of dental implants?
Authors: Turkyilmaz I (I) ; McGlumphy Edwin A (EA) ;
Published in: J Oral Rehabil, 2008 Oct
Read more
Pubmed link
Relationships between implant stability, image-based measures and nitric oxide levels.
Authors: Güncü G N (GN) ; Tözüm T F (TF) ; Güncü M B (MB) ; Yamalik N (N) ;
Published in: J Oral Rehabil, 2008 Oct
Read more
Pubmed link
Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications.
Authors: Sennerby Lars (L) ; Meredith Neil (N) ;
Published in: Periodontol. 2000, 2008
Read more
Pubmed link
Two alternative surgical techniques for enhancing primary implant stability in the posterior maxilla: a clinical study including bone density, insertion torque, and resonance frequency analysis data.
Authors: Turkyilmaz Ilser (I) ; Aksoy Utku (U) ; McGlumphy Edwin A (EA) ;
Published in: Clin Implant Dent Relat Res, 2008 Dec
Read more
Pubmed link