Scientific Database

Educación

Base de datos científica

Nuestra base de datos actualizada periódicamente, en la que hemos compilado todas las investigaciones científicas relacionadas con Osstell y el ISQ, contiene ya más de 1500 artículos.

2017

25 articles

Comparison between tapered and cylindrical implants in the posterior regions of the mandible: A prospective, randomized, split-mouth clinical trial focusing on implant stability changes during early healing.

Date:

2017-01-01 11:00:00

Authors:

Waechter Janine (J) ; Madruga Marina de Matos (MM) ; Carmo Filho Luiz Carlos do (LCD) ; Leite Fábio Renato Manzolli (FRM) ; Schinestsck André Ribeiro (AR) ; Faot Fernanda (F) ;

Published in:

Clin Implant Dent Relat Res

Molar replacement with 7 mm-wide diameter implants: to place the implant immediately or to wait 4 months after socket preservation? 
1 year after loading results from a randomised controlled trial.

Date:

2017-01-01 11:00:00

Authors:

Tallarico Marco (M) ; Xhanari Erta (E) ; Pisano Milena (M) ; Gatti Fulvio (F) ; Meloni Silvio Mario (SM) ;

Published in:

Eur J Oral Implantol

Impacts of 3D bone-to- implant contact and implant diameter on primary stability of dental implant.

Date:

2017-01-01 11:00:00

Authors:

Hsu Jui-Ting (JT) ; Shen Yen-Wen (YW) ; Kuo Chih-Wei (CW) ; Wang Ruei-Teng (RT) ; Fuh Lih-Jyh (LJ) ; Huang Heng-Li (HL) ;

Published in:

J. Formos. Med. Assoc.

Findings from the experience with the punch technique for auditory osseointegrated implants: A retrospective single center comparative study.

Date:

2017-01-01 11:00:00

Authors:

Bonilla Alfonso (A) ; Magri Carlos (C) ; Juan Eulalia (E) ;

Published in:

Acta Otorrinolaringol Esp

A systematic review and meta-analysis of long-term studies (five or more years) assessing maxillary sinus floor augmentation.

Date:

2017-01-01 11:00:00

Authors:

Starch-Jensen T (T) ; Aludden H (H) ; Hallman M (M) ; Dahlin C (C) ; Christensen A-E (AE) ; Mordenfeld A (A) ;

Published in:

Int J Oral Maxillofac Surg

Effect of microthreads on coronal bone healing of narrow-diameter implants with reverse-tapered design in beagle dogs.

Date:

2017-01-01 11:00:00

Authors:

Chang Yun-Young (YY) ; Kim Su-Hwan (SH) ; Park Keun-Oh (KO) ; Yun Jeong-Ho (JH) ;

Published in:

Clin Oral Implants Res

Effects of different loading protocols on the secondary stability and peri-implant bone density of the single implants in the posterior maxilla.

Date:

2017-01-01 11:00:00

Authors:

Akoğlan Mücahide (M) ; Tatli Ufuk (U) ; Kurtoğlu Cem (C) ; Salimov Fariz (F) ; Kürkçü Mehmet (M) ;

Published in:

Clin Implant Dent Relat Res

A New Highly Hydrophilic Electrochemical Implant Titanium Surface: A Histological and Biomechanical In Vivo Study.

Date:

2017-01-01 11:00:00

Authors:

Trisi Paolo (P) ; Berardini Marco (M) ; Falco Antonello (A) ; Sandrini Enrico (E) ; Vulpiani Michele Podaliri (MP) ;

Published in:

Implant Dent

Comparative evaluation of the stability of two different dental implant designs and surgical protocols-a pilot study.

Date:

2017-01-01 11:00:00

Authors:

Simmons David E (DE) ; Maney Pooja (P) ; Teitelbaum Austin G (AG) ; Billiot Susan (S) ; Popat Lomesh J (LJ) ; Palaiologou A Archontia (AA) ;

Published in:

Int J Implant Dent

A resonance frequency analysis of sandblasted and acid-etched implants with different diameters: a prospective clinical study during the initial healing period.

Date:

2017-01-01 11:00:00

Authors:

Kim Hyun-Joo (HJ) ; Kim Yeun-Kang (YK) ; Joo Ji-Young (JY) ; Lee Ju-Youn (JY) ;

Published in:

J Periodontal Implant Sci

The effect of 2 versus 4 implants on implant stability in mandibular overdentures: A randomized controlled trial.

Date:

2017-01-01 11:00:00

Authors:

Al-Magaleh Wafa\’a R (WR) ; Swelem Amal A (AA) ; Radi Iman A W (IA) ;

Published in:

J Prosthet Dent

Monitoring the Changes of Material Properties at Bone-Implant Interface during the Healing Process In Vivo: A Viscoelastic Investigation.

Date:

2017-01-01 11:00:00

Authors:

Chen Hsiang-Ho (HH) ; Lai Wei-Yi (WY) ; Chee Tze-Jian (TJ) ; Chan Ya-Hui (YH) ; Feng Sheng-Wei (SW) ;

Published in:

Biomed Res Int

6-mm-long implants loaded with fiber-reinforced composite resin-bonded fixed prostheses (FRCRBFDPs). A 5-year prospective study.

Date:

2017-01-01 11:00:00

Authors:

Rossi Fabio (F) ; Lang Niklaus P (NP) ; Ricci Emanuele (E) ; Ferraioli Lorenzo (L) ; Marchetti Claudio (C) ; Botticelli Daniele (D) ;

Published in:

Clin Oral Implants Res

A comparative study of the effectiveness of early and delayed loading of short tissue-level dental implants with hydrophilic surfaces placed in the posterior section of the mandible-A preliminary study.

Date:

2017-01-01 11:00:00

Authors:

Makowiecki Arkadiusz (A) ; Botzenhart Ute (U) ; Seeliger Julia (J) ; Heinemann Friedhelm (F) ; Biocev Peter (P) ; Dominiak Marzena (M) ;

Published in:

Ann. Anat.

Immediate loading for implant restoration compared with early or conventional loading: A meta-analysis.

Date:

2017-01-01 11:00:00

Authors:

Zhang Sijia (S) ; Wang Shuyan (S) ; Song Yingliang (Y) ;

Published in:

J Craniomaxillofac Surg

Comparative Study on Osseointegration of Implants After Flap and Flapless Surgery in the Mandible of Dogs.

Date:

2017-01-01 11:00:00

Authors:

Min Hong-Gi (HG) ; Kim Su-Gwan (SG) ; Oh Ji-Su (JS) ; You Jae-Seek (JS) ; Lim Sung-Chul (SC) ; Jeong Mi-Ae (MA) ;

Published in:

Implant Dent

Immediate mechanical stability of threaded and porous implant systems.

Date:

2017-01-01 11:00:00

Authors:

Kim Do-Gyoon (DG) ; Jeong Yong-Hoon (YH) ; Chien Hua-Hong (HH) ; Agnew Amanda M (AM) ; Lee Jin Whan (JW) ; Wen Hai Bo (HB) ;

Published in:

Clin Biomech (Bristol, Avon)

The Use of Cone Beam Computed Tomography in Assessing the Insertion of Bone Conduction Hearing Implants.

Date:

2017-01-01 11:00:00

Authors:

Calon Tim George Ate (TGA) ; Johansson Martin Lars (ML) ; van den Burg Elske Larissa (EL) ; Janssen Anna Maria Louisa (AML) ; van Hoof Marc (M) ; Stokroos Robert Jan (RJ) ;

Published in:

Front Surg

The rate and stability of mandibular block bone graft in recent 5 years.

Date:

2017-01-01 11:00:00

Authors:

Park Jong-Cheol (JC) ; Kim Yun-Ho (YH) ; Choi Hong-Seok (HS) ; Oh Jong-Shik (JS) ; Shin Sang-Hun (SH) ; Kim Yong-Deok (YD) ;

Published in:

Maxillofac Plast Reconstr Surg

Implant Stability of Biological Hydroxyapatites Used in Dentistry.

Date:

2017-01-01 11:00:00

Authors:

Ramírez Fernández Maria Piedad (MP) ; Gehrke Sergio A (SA) ; Mazón Patricia (P) ; Calvo-Guirado Jose L (JL) ; De Aza Piedad N (PN) ;

Published in:

Materials (Basel)

A stepwise under-prepared osteotomy technique improves primary stability in shallow-placed implants: a preliminary study for simultaneous vertical ridge augmentation.

Date:

2017-01-01 11:00:00

Authors:

Ueno Daisuke (D) ; Nakamura Kei (K) ; Kojima Kousuke (K) ; Toyoshima Takeshi (T) ; Tanaka Hideaki (H) ; Ueda Kazuhiko (K) ; Koyano Kiyoshi (K) ; Kodama Toshiro (T) ;

Published in:

Odontology

Clinical, radiological, and gene expression analyses in smokers and non-smokers, Part 2: RCT on the late healing phase of osseointegration.

Date:

2017-01-01 11:00:00

Authors:

Sayardoust Shariel (S) ; Omar Omar (O) ; Norderyd Ola (O) ; Thomsen Peter (P) ;

Published in:

Clin Implant Dent Relat Res

Relationship between implant stability on the abutment and platform level by means of resonance frequency analysis: A cross-sectional study.

Date:

2017-01-01 11:00:00

Authors:

Lages Frederico Santos (FS) ; Willya Douglas-de-Oliveira Dhelfeson (D) ; Ibelli Guilherme Siqueira (GS) ; Assaf Fatimah (F) ; Queiroz Thallita Pereira (TP) ; Costa Fernando Oliveira (FO) ;

Published in:

PLoS ONE

Comparison between inflammation-related markers in peri-implant crevicular fluid and clinical parameters during osseointegration in edentulous jaws.

Date:

2017-01-01 11:00:00

Authors:

Bielemann Amália M (AM) ; Marcello-Machado Raissa M (RM) ; Leite Fábio Renato Manzolli (FRM) ; Martinho Frederico Canato (FC) ; Chagas-Júnior Otacílio Luiz (OL) ; Antoninha Del Bel Cury Altair (A) ; Faot Fernanda (F) ;

Published in:

Clin Oral Investig

Bone tissue response following local drug delivery of bisphosphonate through titanium oxide nanotube implants in a rabbit model.

Date:

2017-01-01 11:00:00

Authors:

Kwon David H (DH) ; Lee Sang J (SJ) ; Wikesjö Ulf M E (UME) ; Johansson Petra H (PH) ; Johansson Carina B (CB) ; Sul Young-Taeg (YT) ;

Published in:

J. Clin. Periodontol.